1. Cooler air, a smaller rating
A capacity is the amount of water removed per day under the rating method. Cooler air contains less moisture, so the same appliance can earn a lower capacity figure. A new label is not proof that a comparable machine got weaker.
Old rating
80°F
Historical portable test conditions.
DOE 2019
65°F
Current portable capacity · 60% RH.
Whole-home units use a 73°F test. Keep those figures separate from portables.
2. From a chart to a shopping class
The historical AHAM chart is a starting point. Our shared sizing tool uses conservative class bins: old 30 → current 20, 50 → 35, and 70 → 50, followed by one class up for a basement or crawl space.
These are editorial shopping bins. ENERGY STAR’s rough model correlations differ: old 50 ≈ new 30, old 60 ≈ new 35, old 70 ≈ new 40–45. No table converts every model exactly.
| Area · sq ft | Moderately damp | Very damp | Wet | Extremely wet |
|---|---|---|---|---|
| 500 | 20 pt/day class 10 pt/day · AHAM at 80°F | 20 pt/day class 12 pt/day · AHAM at 80°F | 20 pt/day class 14 pt/day · AHAM at 80°F | 20 pt/day class 16 pt/day · AHAM at 80°F |
| 1,000 | 20 pt/day class 14 pt/day · AHAM at 80°F | 20 pt/day class 17 pt/day · AHAM at 80°F | 20 pt/day class 20 pt/day · AHAM at 80°F | 20 pt/day class 23 pt/day · AHAM at 80°F |
| 1,500 | 20 pt/day class 18 pt/day · AHAM at 80°F | 20 pt/day class 22 pt/day · AHAM at 80°F | 20 pt/day class 26 pt/day · AHAM at 80°F | 20 pt/day class 30 pt/day · AHAM at 80°F |
| 2,000 | 20 pt/day class 22 pt/day · AHAM at 80°F | 20 pt/day class 27 pt/day · AHAM at 80°F | 35 pt/day class 32 pt/day · AHAM at 80°F | 35 pt/day class 37 pt/day · AHAM at 80°F |
| 2,500 | 20 pt/day class 26 pt/day · AHAM at 80°F | 35 pt/day class 32 pt/day · AHAM at 80°F | 35 pt/day class 38 pt/day · AHAM at 80°F | 35 pt/day class 44 pt/day · AHAM at 80°F |
3. “Box”, “label” and “maker’s claim” are different
The box is marketing copy printed on the package or listing. A historical label is the capacity class under the older rating era. A maker’s claim is a manual or manufacturer specification that a public database has not confirmed.
Waykar CTH120A: certified capacity source · checked Oct 11, 2026. Check the claim’s stated conditions in the source library; it is not a portable 65°F capacity.
4. Choose drainage after sizing
A correct capacity will not solve an awkward hose route. A gravity drain needs a downward run. A pump needs enough rated lift and an installation that matches the manual.
See the basement picks and their source notes →Sources & checks