Mini Split Size Calculator
A starting estimate for one room. Size for the load, then check the heating numbers.
Mini split size chart
| Area · sq ft | Estimate · BTU/h | Next standard head |
|---|---|---|
| 400 | 8,800 | 9k |
| 500 | 11,000 | 12k |
| 600 | 13,200 | 18k |
| 800 | 17,600 | 18k |
| 1000 | 22,000 | 24k |
| 1200 | 26,400 | 36k |
How we estimate
Area × 22 × ceiling height ÷ 8. Multiply by 1.2 for poor insulation or 0.9 for good insulation; by 1.1 for sunny exposure or 0.9 for shade. Add 600 BTU/h per person above two, 4,000 for a kitchen or 2,000 for a garage. The displayed planning range is ±15%. These are our screening assumptions, not a published load-calculation standard.
Climate zone triggers the cold-climate warning; it does not replace a heating-load calculation. Room separation and air distribution may require more than one head.
Compare SEER2, HSPF2 and cold-weather capacity →Sources & checks
View all 2 source records and check dates
- ENERGY STAR room AC sizing — Room sizing considerations; not a mini split load calculation. Checked 2026-10-16
- NEEP cold-climate heat pump list — Check low-temperature capacity for the exact outdoor/indoor match. Checked 2026-10-16