Portable AC BTU: SACC vs ASHRAE

HomeClimateScout's short answer: size a portable air conditioner by its SACC, the Department of Energy's capacity figure, not the larger ASHRAE number. In the DOE records we compared, SACC was 17% to 33% lower than the ASHRAE figure on the same box. A "14,000 BTU" portable is usually a 10,000 BTU SACC unit.

Most portable AC boxes carry two BTU figures, like "14,000 BTU (ASHRAE) / 10,000 BTU (SACC)". They describe the same machine measured two ways. They are not interchangeable, and which one you use decides whether the room gets cool.

What SACC measures

SACC stands for seasonally adjusted cooling capacity. It's the capacity each model must be certified at under DOE's test procedure for portable air conditioners (10 CFR 430, Appendix CC), and it's the figure in DOE's public compliance database.

The test does two things the bigger number doesn't:

  • It accounts for the hose and the leaks. DOE measures the heat that comes back into the room through the warm exhaust duct, and the heat from outdoor air that gets drawn into the room to replace the air a portable blows outside. Both are subtracted from the cooling the unit delivers.
  • It averages two conditions. The unit is tested at 95°F and at 83°F outdoors, and the results are weighted 20% and 80%. That reflects that most cooling hours aren't the hottest afternoon of the year.

The same test produces the CEER (combined energy efficiency ratio): cooling delivered per watt-hour of electricity, including standby power. Since January 10, 2025, every portable AC made for or imported into the US must meet a minimum CEER under DOE's standards.

What the ASHRAE number measures

The ASHRAE figure comes from an industry test standard (LG's spec sheet names it: ASHRAE 128). It doesn't include the deductions DOE's test makes for heat from the exhaust duct and from infiltration air, and it isn't averaged across two outdoor temperatures. That's why it's bigger.

Makers still print it, often in the largest type, because it was the industry's headline figure before the DOE test. It isn't false. But it describes the machine rather than your room, and it's the number behind most "this AC can't keep up" complaints.

Real pairs from DOE records

We compared the maker's ASHRAE figure with the DOE-certified SACC for seven portable models in our library, as of DOE data read on 2026-10-11.

ModelHosesInverterASHRAE (maker)SACC (DOE)SACC below ASHRAE
Frigidaire FHPC082AC1SingleNo8,0005,50031%
Frigidaire FHPW122AC1SingleNo12,0008,00033%
LG LP1419IVSMSingleYes14,00010,00029%
Whynter ARC-147WFDualNo14,00010,00029%
Dreo DR-HAC010SDualYes14,00010,00029%
Midea Duo MAP12S1TBLHose-in-hoseYes12,00010,00017%

Two things stand out. First, three different 14,000 BTU boxes are all 10,000 BTU SACC: one single-hose, one dual-hose, one dual-hose inverter. The ASHRAE label told you nothing about which one cools more. Second, the gap isn't a fixed ratio. The Midea Duo's is 17%, the others' about 30%, so a rule like "subtract a third" would undersell the Midea.

Where the hose design does show is efficiency. At the same 10,000 BTU SACC, the single-hose LG has a CEER of 7.9 and the dual-hose Whynter 7.8, while the dual-duct inverters reach 12.2 (Dreo) and 14.7 (Midea Duo 12K). The seventh model we looked at, BLACK+DECKER's BPACT14WT, is left out of the table: DOE lists 10,200 BTU SACC, while Black+Decker's own site says 7,700.

What size portable AC do you need?

ENERGY STAR publishes a sizing chart for room air conditioners. It's the clearest public guide, and we apply it to a portable's SACC. Because SACC is the lower, loss-adjusted figure, matching it to the chart is the conservative choice: you won't undersize by reading the box's bigger number.

Room area (sq ft)Capacity needed (ENERGY STAR, BTU/h)Look for this SACCExample in our library (SACC / ASHRAE)
100 to 1505,0005,000+Frigidaire FHPC082AC1: 5,500 / 8,000
150 to 2506,0006,000+LG LP0626PWSF: 6,000 SACC
250 to 3007,0007,000+Midea MAP07S1AWT-A: 7,100 SACC
300 to 3508,0008,000+Frigidaire FHPW122AC1: 8,000 / 12,000
350 to 4009,0009,000+A 10,000 SACC unit
400 to 45010,00010,000+Dreo DR-HAC010S: 10,000 / 14,000
450 to 55012,00012,000+Midea Duo 14K with Heat: 12,000 SACC
550 to 70014,00014,000+None in our library. Consider two units or a mini split.

ENERGY STAR's adjustments apply too:

  • Very sunny room: add 10%.
  • Heavily shaded room: subtract 10%.
  • More than two people regularly in the room: add 600 BTU per extra person.
  • Kitchen: add 4,000 BTU.

The chart assumes ordinary ceilings, so a tall or vaulted room needs more. Where we could find only a SACC figure, as for the LG LP0626PWSF (from DOE) and the Midea MAP07S1AWT-A, that's all you need.

Inverter portables have two SACC figures

A variable-speed (inverter) portable can run its compressor slower once the room is cool, so DOE tests it twice at the milder 83°F condition: once at full speed and once at low speed.

  • SACC, the headline figure, combines the 95°F full-speed test with the 83°F low-speed test, weighted 20% and 80%. This is the capacity the unit delivers in its normal, throttled-back running.
  • Full-load SACC combines the 95°F test with the 83°F full-speed test, with the same weighting. This tells you how much the unit can deliver when it's working flat out.

For sizing a room, use the headline SACC, as you would for any portable. DOE's database lists both for inverter models, and for some they're the same: the Midea Duo 12K's record shows 10,000 BTU for each. If an inverter model's full-load figure is noticeably higher, it has extra capacity for heat waves or for cooling a room down quickly after you get home.

Single-speed units have only the one SACC, because their compressor has only one speed.

Common mistakes when reading the box

  • Sizing on the biggest number. The largest type on the box is often the ASHRAE figure. Size on SACC.
  • Comparing an ASHRAE figure with a SACC figure. A "12,000 BTU" unit from one brand and a "10,000 BTU" unit from another may be the same capacity, or the reverse. Put both on the SACC basis first.
  • Reading "Dual Inverter" as dual hose. On LG's portables it describes the compressor. DOE lists the LP1419IVSM as single-duct.
  • Ignoring CEER. Two units with the same SACC can differ by almost two to one on running cost.

Where to find a model's SACC

  • On the box or listing. Look for "SACC", "DOE" or "BTU (DOE)". "Seasonally adjusted" means the same thing.
  • On the maker's spec sheet. Frigidaire's sheets, for example, list "DOE BTU (Cool)".
  • In DOE's database. The Compliance Certification Database lets you search by model number for the certified SACC, CEER, duct configuration and whether the compressor is variable speed.

If a listing only shows one BTU figure and doesn't say which, assume it's the ASHRAE one until you find otherwise.

Single hose, dual hose and SACC

A single-hose (single-duct) portable draws all its condenser air from the room and blows it outside. That makes the room slightly negative in pressure, so warm outdoor air leaks back in through gaps around doors and windows. A dual-hose (dual-duct) portable draws condenser air from outdoors through a second hose, so less room air is thrown away.

DOE's test measures that infiltration directly, so it's already in a model's SACC and CEER. Compare those figures rather than the number of hoses. In our records, the dual-hose units with inverters were the efficient ones; a dual-hose unit without an inverter rated about the same as a good single-hose model.

Next steps

All our portable AC pages are on the portable air conditioners hub.

Questions people ask

What is the difference between SACC and ASHRAE?

They are two different test bases for the same machine. ASHRAE is the industry rating most makers print in large type. SACC (seasonally adjusted cooling capacity) is the Department of Energy's figure. It weights tests at 95°F and 83°F outdoors and subtracts the heat that leaks in through the hot exhaust hose and from outdoor air pulled into the room. SACC is lower, and it's the one to compare.

Which BTU rating should I use to size a portable AC?

Use SACC. Match the SACC figure to your room's floor area with a sizing chart. Using the larger ASHRAE figure is how people end up with a portable that can't keep a room cool.

How much lower is SACC than ASHRAE?

In the seven DOE records we compared, SACC was 17% to 33% below the maker's ASHRAE figure. A unit sold as 14,000 BTU (ASHRAE) was typically 10,000 BTU SACC. There's no fixed conversion, so read both numbers from the box or the maker's spec sheet.

Can I convert ASHRAE BTU to SACC?

Not reliably. The two come from different tests, and the gap varies by model. Look up the model's SACC on the box, the maker's spec sheet or the DOE Compliance Certification Database.

What size portable AC do I need for 400 square feet?

ENERGY STAR's chart suggests 9,000 BTU for 350 to 400 sq ft and 10,000 BTU for 400 to 450 sq ft. For a portable, look for that figure as SACC. Several 14,000 BTU (ASHRAE) models in our library are 10,000 BTU SACC.

What is CEER on a portable air conditioner?

CEER (combined energy efficiency ratio) is DOE's efficiency rating: cooling delivered per watt-hour of electricity under the same test as SACC, including standby power. Higher is better. The portables in our library range from 6.3 to 14.7.

Sources & checks